Campaign (experimental)
A Campaign is one bounded, fully autonomous measurement run that starts when the unit is switched on. It is meant for a quick survey of a site without a computer: power on, walk away, read the satellite report.
How to use it
Section titled “How to use it”-
Advanced → Settings → Schedule → Campaign — Experimental: tick it and choose the duration (15–1440 minutes, 60 by default). Save to the unit.


Simulator The Campaign card in Settings → Schedule, ticked, with its duration.
-
Switch the unit off and remove every power source (USB unplugged, switch off), then switch it on at the site. Every physical power-on starts a new run while Campaign is enabled.
-
Leave it. The unit:
- waits for a fresh position fix (horizontal accuracy ≤ 10 m, stable, with GNSS time; at most 5 minutes);
- records for the chosen duration with GPS, Galileo, BeiDou and GLONASS, all azimuths, elevation 5–25°, automatic sampling and automatic reflector-height range;
- processes and saves the results;
- switches the receiver off and sends a final Iridium report (installation diagnostics, health, position when available), with one retry after 30 minutes.
-
Afterwards, connect the app to download the records, then disable Campaign (otherwise the next power-on starts another run and another paid report).
The normal station settings are not changed; the daily schedule is suspended while Campaign is enabled.
If something goes wrong during the run
Section titled “If something goes wrong during the run”| Event | What the unit does |
|---|---|
| Watchdog, brown-out, software reset | Resumes the run up to the original deadline (or goes straight to saving and reporting if the deadline has passed). At most two recoveries per power-on; a third reset only reports what is saved. |
| Requested reboot (e.g. firmware update) | Resumes; does not count as a failure. |
| No fix within 5 minutes | Still sends a report (no position, no water result is invented). |
| Low battery / modem blocked | Waits; the battery guard and airtime budget always win. |
| Report already delivered | A reset never sends it again. |
Switching the power off with USB still connected is a reset, not a power-on: an unfinished run resumes instead of starting anew.
How to read the results
Section titled “How to read the results”All-azimuth reflections are not confirmed water: terrain, buildings
and vegetation also reflect. A Campaign tells you whether, and in which
directions, the site produces usable reflections and roughly at what
height. Operational measurements need a normal installation with sectors
aimed at the water. Records of a Campaign are flagged
EXPERIMENTAL_CAMPAIGN over USB; the Iridium summary does not carry that
flag, so the receiving side must know which units run campaigns.